What size mini split does a 600 sq ft bedroom in Lenexa, KS need?

600 ft² bedroom in Lenexa, KS
15,000BTU/hr
13,565 BTU/hr of load at 22.6 BTU/ft² — the figure for 1,546 cooling degree days
600 ft² bedroom in Lenexa, KS15,000 BTU/hrHead size to buy13,565 BTU/hrCalculated load12,000 BTU/hrWhat the 20 BTU/f…
Head size to buy15,000BTU/hr
Calculated load600 ft² × 22.6 BTU/ft²13,565BTU/hr
BTU per square foot hereinterpolated from Lenexa's 1,546 cooling degree days22.6BTU/ft²
What the 20 BTU/ft² rule givesthis room needs 13% more than the rule says12,000BTU/hr
Summer design temperature95°F
Winter design temperaturea mini split heats too — this is the number that decides whether it can carry the room alone2°F
Summer day–night swinga fairly dry climate21°F
Days at or above 90°F39days/yr
Oversize from the size stepwithin the normal step11%

Notes

  • The "20 BTU per square foot" rule is a Midwest number. Lenexa runs 1,546 cooling degree days, which works out to 22.6 BTU/ft² — so for this bedroom the rule is 13% short. A single national figure has to be wrong somewhere, and this is where.
  • Bedroom: the room where oversizing hurts most — quiet, low load, long runtimes wanted.
  • 15,000 BTU/hr sits close to the load, which is where a mini split works best. Inverter equipment is happiest running long and slow at part load; it is the short, hard cycles of an oversized head that leave a room cold and damp.
  • Lenexa is fairly dry — summer nights stay within 21°F of the day's high, the signature of humid air. A meaningful share of this head's work is removing moisture, and it only removes moisture while it is running. This is the climate where an oversized head produces a room that reads cold and feels clammy.
  • Do not forget the winter side. Lenexa designs to 2°F. That is cold enough that a standard head will have lost a large part of its rated capacity by the time it is needed most — check the manufacturer's capacity table at 2°F, not the nameplate, and look at hyper-heat rated equipment.
  • Where these numbers come from. Olathe / Clare, 19 km from downtown Lenexa, daily records 2015–2024. Design temperatures are calibrated against published ASHRAE values at eight airports and land within about 2°F of them.

The short answer

A 600 square foot bedroom in Lenexa, KS needs a head of about 15,000 BTU per hour. The calculated load is 13,565 BTU/hr.

Where that number comes from

Lenexa, KS runs 1,546 cooling degree days a year, which puts the room at 22.6 BTU per square foot rather than the 20 BTU/ft² the generic charts use. Applied to this room the rule gives 12,000 BTU/hr.

The winter half of the question

Lenexa, KS designs to 2°F. A mini split is a heat pump, and its heating capacity falls as the outdoor temperature drops — the nameplate is measured at 47°F, not at the temperature you actually need it.

Sizing a single room is not sizing a house

There is no other room to absorb a mistake. An oversized head short-cycles, never runs long enough to dehumidify, and leaves the room cold and damp.