ZoneBtuBTU per head, per room, per orientation — not one number for the house.

What size mini split does a 800 sq ft living room in Sterling Heights, MI need?

800 ft² living room in Sterling Heights, MI
18,000BTU/hr
17,717 BTU/hr of load at 20.1 BTU/ft² — the figure for 976 cooling degree days
800 ft² living room in Sterling Heights, MI18,000 BTU/hrHead size to buy17,717 BTU/hrCalculated load17,600 BTU/hrWhat the 20 BTU/f…
Head size to buy18,000BTU/hr
Calculated load800 ft² × 20.1 BTU/ft² × 1.1 for a living room17,717BTU/hr
BTU per square foot hereinterpolated from Sterling Heights's 976 cooling degree days20.1BTU/ft²
What the 20 BTU/ft² rule givesthis room needs 1% more than the rule says17,600BTU/hr
Summer design temperature89°F
Winter design temperaturea mini split heats too — this is the number that decides whether it can carry the room alone1°F
Summer day–night swinga moderately humid climate19°F
Days at or above 90°F9days/yr
Oversize from the size stepwithin the normal step2%

Notes

  • The "20 BTU per square foot" rule is a Midwest number. Sterling Heights runs 976 cooling degree days, which works out to 20.1 BTU/ft² — so for this living room the rule is 1% short. A single national figure has to be wrong somewhere, and this is where.
  • Living room: more people, more glazing, more electronics. The 1.1× factor accounts for that.
  • 18,000 BTU/hr sits close to the load, which is where a mini split works best. Inverter equipment is happiest running long and slow at part load; it is the short, hard cycles of an oversized head that leave a room cold and damp.
  • Sterling Heights is moderately humid — summer nights stay within 19°F of the day's high, the signature of humid air. A meaningful share of this head's work is removing moisture, and it only removes moisture while it is running. This is the climate where an oversized head produces a room that reads cold and feels clammy.
  • Do not forget the winter side. Sterling Heights designs to 1°F. That is cold enough that a standard head will have lost a large part of its rated capacity by the time it is needed most — check the manufacturer's capacity table at 1°F, not the nameplate, and look at hyper-heat rated equipment.
  • Where these numbers come from. Detroit Metropolitan, 39 km from downtown Sterling Heights, daily records 2015–2024. Design temperatures are calibrated against published ASHRAE values at eight airports and land within about 2°F of them.

The short answer

A 800 square foot living room in Sterling Heights, MI needs a head of about 18,000 BTU per hour. The calculated load is 17,717 BTU/hr.

Where that number comes from

Sterling Heights, MI runs 976 cooling degree days a year, which puts the room at 20.1 BTU per square foot rather than the 20 BTU/ft² the generic charts use. Applied to this room the rule gives 17,600 BTU/hr.

The winter half of the question

Sterling Heights, MI designs to 1°F. A mini split is a heat pump, and its heating capacity falls as the outdoor temperature drops — the nameplate is measured at 47°F, not at the temperature you actually need it.

Sizing a single room is not sizing a house

There is no other room to absorb a mistake. An oversized head short-cycles, never runs long enough to dehumidify, and leaves the room cold and damp.

Nearby sizes

Read more