What size mini split does a 800 sq ft living room in Sioux Falls, SD need?

800 ft² living room in Sioux Falls, SD
18,000BTU/hr
17,494 BTU/hr of load at 19.9 BTU/ft² — the figure for 931 cooling degree days
800 ft² living room in Sioux Falls, SD18,000 BTU/hrHead size to buy17,494 BTU/hrCalculated load17,600 BTU/hrWhat the 20 BTU/f…
Head size to buy18,000BTU/hr
Calculated load800 ft² × 19.9 BTU/ft² × 1.1 for a living room17,494BTU/hr
BTU per square foot hereinterpolated from Sioux Falls's 931 cooling degree days19.9BTU/ft²
What the 20 BTU/ft² rule givesthe rule overshoots by 1% here17,600BTU/hr
Summer design temperature91°F
Winter design temperaturea mini split heats too — this is the number that decides whether it can carry the room alone-12°F
Summer day–night swinga fairly dry climate22°F
Days at or above 90°F19days/yr
Oversize from the size stepwithin the normal step3%

Notes

  • The "20 BTU per square foot" rule is a Midwest number. Sioux Falls runs 931 cooling degree days, which works out to 19.9 BTU/ft² — so for this living room the rule overshoots by 1%. A single national figure has to be wrong somewhere, and this is where.
  • Living room: more people, more glazing, more electronics. The 1.1× factor accounts for that.
  • 18,000 BTU/hr sits close to the load, which is where a mini split works best. Inverter equipment is happiest running long and slow at part load; it is the short, hard cycles of an oversized head that leave a room cold and damp.
  • Sioux Falls is dry — nights fall 22°F below the afternoon high, which only happens when there is little water in the air. Latent load is small, so nearly all of the head's capacity goes into temperature. A slightly undersized head is forgiving here: it simply runs longer.
  • Do not forget the winter side. Sioux Falls designs to -12°F. That is cold enough that a standard head will have lost a large part of its rated capacity by the time it is needed most — check the manufacturer's capacity table at -12°F, not the nameplate, and look at hyper-heat rated equipment.
  • Where these numbers come from. Sioux Falls Foss Field, 5 km from downtown Sioux Falls, daily records 2015–2024. Design temperatures are calibrated against published ASHRAE values at eight airports and land within about 2°F of them.

The short answer

A 800 square foot living room in Sioux Falls, SD needs a head of about 18,000 BTU per hour. The calculated load is 17,494 BTU/hr.

Where that number comes from

Sioux Falls, SD runs 931 cooling degree days a year, which puts the room at 19.9 BTU per square foot rather than the 20 BTU/ft² the generic charts use. Applied to this room the rule gives 17,600 BTU/hr.

The winter half of the question

Sioux Falls, SD designs to -12°F. A mini split is a heat pump, and its heating capacity falls as the outdoor temperature drops — the nameplate is measured at 47°F, not at the temperature you actually need it.

Sizing a single room is not sizing a house

There is no other room to absorb a mistake. An oversized head short-cycles, never runs long enough to dehumidify, and leaves the room cold and damp.