What size mini split does a 800 sq ft living room in Portland, OR need?
800 ft² living room in Portland, OR
18,000BTU/hr
16,137 BTU/hr of load at 18.3 BTU/ft² — the figure for 699 cooling degree days
| Head size to buy | 18,000BTU/hr |
|---|---|
| Calculated load800 ft² × 18.3 BTU/ft² × 1.1 for a living room | 16,137BTU/hr |
| BTU per square foot hereinterpolated from Portland's 699 cooling degree days | 18.3BTU/ft² |
| What the 20 BTU/ft² rule givesthe rule overshoots by 8% here | 17,600BTU/hr |
| Summer design temperature | 92°F |
| Winter design temperaturea mini split heats too — this is the number that decides whether it can carry the room alone | 25°F |
| Summer day–night swinga fairly dry climate | 23°F |
| Days at or above 90°F | 20days/yr |
| Oversize from the size stepwithin the normal step | 12% |
Notes
- The "20 BTU per square foot" rule is a Midwest number. Portland runs 699 cooling degree days, which works out to 18.3 BTU/ft² — so for this living room the rule overshoots by 8%. A single national figure has to be wrong somewhere, and this is where.
- Living room: more people, more glazing, more electronics. The 1.1× factor accounts for that.
- 18,000 BTU/hr sits close to the load, which is where a mini split works best. Inverter equipment is happiest running long and slow at part load; it is the short, hard cycles of an oversized head that leave a room cold and damp.
- Portland is dry — nights fall 23°F below the afternoon high, which only happens when there is little water in the air. Latent load is small, so nearly all of the head's capacity goes into temperature. A slightly undersized head is forgiving here: it simply runs longer.
- Do not forget the winter side. Portland designs to 25°F. A cold-climate rated head will hold most of its capacity there, but a standard one will not — ask for the capacity at 25°F in writing.
- Where these numbers come from. Portland International Airport, 9 km from downtown Portland, daily records 2015–2024. Design temperatures are calibrated against published ASHRAE values at eight airports and land within about 2°F of them.
The short answer
A 800 square foot living room in Portland, OR needs a head of about 18,000 BTU per hour. The calculated load is 16,137 BTU/hr.
Where that number comes from
Portland, OR runs 699 cooling degree days a year, which puts the room at 18.3 BTU per square foot rather than the 20 BTU/ft² the generic charts use. Applied to this room the rule gives 17,600 BTU/hr.
The winter half of the question
Portland, OR designs to 25°F. A mini split is a heat pump, and its heating capacity falls as the outdoor temperature drops — the nameplate is measured at 47°F, not at the temperature you actually need it.
Sizing a single room is not sizing a house
There is no other room to absorb a mistake. An oversized head short-cycles, never runs long enough to dehumidify, and leaves the room cold and damp.
Nearby sizes
- What size mini split does a 800 sq ft living room in Boston, MA need?
- What size mini split does a 800 sq ft living room in Detroit, MI need?
- What size mini split does a 800 sq ft living room in El Paso, TX need?
- What size mini split does a 800 sq ft living room in Las Vegas, NV need?
- What size mini split does a 600 sq ft living room in Portland, OR need?
- What size mini split does a 800 sq ft bedroom in Portland, OR need?
Read more
- Mini Split Blowing Cold Air in Heat Mode — Defrost, UsuallyEvery air-source heat pump does this. Knowing what a defrost cycle looks like is the difference between waiting ten minutes and calling somebody out.
- Mini Split Leaking Water Indoors — Four Causes, One CommonA cooling head makes a couple of litres a day. It leaves through a small pipe with no pump behind it, and that pipe is where nearly every leak starts.
- Multi-Zone Mini Split Not Cooling Every Room — The Minimum Output ProblemThe system is not underpowered. It is oversized for the one room that is calling, and multi-zone units handle that far worse than single-zone ones.