ZoneBtuBTU per head, per room, per orientation — not one number for the house.

What size mini split does a 800 sq ft living room in Lorain, OH need?

800 ft² living room in Lorain, OH
18,000BTU/hr
17,921 BTU/hr of load at 20.4 BTU/ft² — the figure for 1,019 cooling degree days
800 ft² living room in Lorain, OH18,000 BTU/hrHead size to buy17,921 BTU/hrCalculated load17,600 BTU/hrWhat the 20 BTU/f…
Head size to buy18,000BTU/hr
Calculated load800 ft² × 20.4 BTU/ft² × 1.1 for a living room17,921BTU/hr
BTU per square foot hereinterpolated from Lorain's 1,019 cooling degree days20.4BTU/ft²
What the 20 BTU/ft² rule givesthis room needs 2% more than the rule says17,600BTU/hr
Summer design temperature90°F
Winter design temperaturea mini split heats too — this is the number that decides whether it can carry the room alone3°F
Summer day–night swinga moderately humid climate18°F
Days at or above 90°F11days/yr
Oversize from the size stepwithin the normal step0%

Notes

  • The "20 BTU per square foot" rule is a Midwest number. Lorain runs 1,019 cooling degree days, which works out to 20.4 BTU/ft² — so for this living room the rule is 2% short. A single national figure has to be wrong somewhere, and this is where.
  • Living room: more people, more glazing, more electronics. The 1.1× factor accounts for that.
  • 18,000 BTU/hr sits close to the load, which is where a mini split works best. Inverter equipment is happiest running long and slow at part load; it is the short, hard cycles of an oversized head that leave a room cold and damp.
  • Lorain is moderately humid — summer nights stay within 18°F of the day's high, the signature of humid air. A meaningful share of this head's work is removing moisture, and it only removes moisture while it is running. This is the climate where an oversized head produces a room that reads cold and feels clammy.
  • Do not forget the winter side. Lorain designs to 3°F. That is cold enough that a standard head will have lost a large part of its rated capacity by the time it is needed most — check the manufacturer's capacity table at 3°F, not the nameplate, and look at hyper-heat rated equipment.
  • Where these numbers come from. Cleveland-Hopkins International, 28 km from downtown Lorain, daily records 2015–2024. Design temperatures are calibrated against published ASHRAE values at eight airports and land within about 2°F of them.

The short answer

A 800 square foot living room in Lorain, OH needs a head of about 18,000 BTU per hour. The calculated load is 17,921 BTU/hr.

Where that number comes from

Lorain, OH runs 1,019 cooling degree days a year, which puts the room at 20.4 BTU per square foot rather than the 20 BTU/ft² the generic charts use. Applied to this room the rule gives 17,600 BTU/hr.

The winter half of the question

Lorain, OH designs to 3°F. A mini split is a heat pump, and its heating capacity falls as the outdoor temperature drops — the nameplate is measured at 47°F, not at the temperature you actually need it.

Sizing a single room is not sizing a house

There is no other room to absorb a mistake. An oversized head short-cycles, never runs long enough to dehumidify, and leaves the room cold and damp.

Nearby sizes

Read more