What size mini split does a 800 sq ft bedroom in Tucson, AZ need?

800 ft² bedroom in Tucson, AZ
24,000BTU/hr
21,829 BTU/hr of load at 27.3 BTU/ft² — the figure for 3,689 cooling degree days
800 ft² bedroom in Tucson, AZ24,000 BTU/hrHead size to buy21,829 BTU/hrCalculated load16,000 BTU/hrWhat the 20 BTU/f…
Head size to buy24,000BTU/hr
Calculated load800 ft² × 27.3 BTU/ft²21,829BTU/hr
BTU per square foot hereinterpolated from Tucson's 3,689 cooling degree days27.3BTU/ft²
What the 20 BTU/ft² rule givesthis room needs 36% more than the rule says16,000BTU/hr
Summer design temperature107°F
Winter design temperaturea mini split heats too — this is the number that decides whether it can carry the room alone30°F
Summer day–night swinga dry climate26°F
Days at or above 90°F159days/yr
Oversize from the size stepwithin the normal step10%

Notes

  • The "20 BTU per square foot" rule is a Midwest number. Tucson runs 3,689 cooling degree days, which works out to 27.3 BTU/ft² — so for this bedroom the rule is 36% short. A single national figure has to be wrong somewhere, and this is where.
  • Bedroom: the room where oversizing hurts most — quiet, low load, long runtimes wanted.
  • 24,000 BTU/hr sits close to the load, which is where a mini split works best. Inverter equipment is happiest running long and slow at part load; it is the short, hard cycles of an oversized head that leave a room cold and damp.
  • Tucson is dry — nights fall 26°F below the afternoon high, which only happens when there is little water in the air. Latent load is small, so nearly all of the head's capacity goes into temperature. A slightly undersized head is forgiving here: it simply runs longer.
  • Do not forget the winter side. Tucson designs to 30°F. That is mild enough that heating capacity is not the constraint here; size for cooling and the heating follows.
  • Where these numbers come from. Tucson International Airport, 10 km from downtown Tucson, daily records 2015–2024. Design temperatures are calibrated against published ASHRAE values at eight airports and land within about 2°F of them.

The short answer

A 800 square foot bedroom in Tucson, AZ needs a head of about 24,000 BTU per hour. The calculated load is 21,829 BTU/hr.

Where that number comes from

Tucson, AZ runs 3,689 cooling degree days a year, which puts the room at 27.3 BTU per square foot rather than the 20 BTU/ft² the generic charts use. Applied to this room the rule gives 16,000 BTU/hr.

The winter half of the question

Tucson, AZ designs to 30°F. A mini split is a heat pump, and its heating capacity falls as the outdoor temperature drops — the nameplate is measured at 47°F, not at the temperature you actually need it.

Sizing a single room is not sizing a house

There is no other room to absorb a mistake. An oversized head short-cycles, never runs long enough to dehumidify, and leaves the room cold and damp.