What size mini split does a 800 sq ft bedroom in San Francisco, CA need?
800 ft² bedroom in San Francisco, CA
12,000BTU/hr
10,430 BTU/hr of load at 13 BTU/ft² — the figure for 261 cooling degree days
| Head size to buy | 12,000BTU/hr |
|---|---|
| Calculated load800 ft² × 13 BTU/ft² | 10,430BTU/hr |
| BTU per square foot hereinterpolated from San Francisco's 261 cooling degree days | 13BTU/ft² |
| What the 20 BTU/ft² rule givesthe rule overshoots by 35% here | 16,000BTU/hr |
| Summer design temperature | 85°F |
| Winter design temperaturea mini split heats too — this is the number that decides whether it can carry the room alone | 35°F |
| Summer day–night swinga moderately humid climate | 16°F |
| Days at or above 90°F | 6days/yr |
| Oversize from the size stepwithin the normal step | 15% |
Notes
- The "20 BTU per square foot" rule is a Midwest number. San Francisco runs 261 cooling degree days, which works out to 13 BTU/ft² — so for this bedroom the rule overshoots by 35%. A single national figure has to be wrong somewhere, and this is where.
- Bedroom: the room where oversizing hurts most — quiet, low load, long runtimes wanted.
- 12,000 BTU/hr sits close to the load, which is where a mini split works best. Inverter equipment is happiest running long and slow at part load; it is the short, hard cycles of an oversized head that leave a room cold and damp.
- San Francisco is moderately humid — summer nights stay within 16°F of the day's high, the signature of humid air. A meaningful share of this head's work is removing moisture, and it only removes moisture while it is running. This is the climate where an oversized head produces a room that reads cold and feels clammy.
- Do not forget the winter side. San Francisco designs to 35°F. That is mild enough that heating capacity is not the constraint here; size for cooling and the heating follows.
- Where these numbers come from. Metro Oakland International Airport, 18 km from downtown San Francisco, daily records 2015–2024. Design temperatures are calibrated against published ASHRAE values at eight airports and land within about 2°F of them.
The short answer
A 800 square foot bedroom in San Francisco, CA needs a head of about 12,000 BTU per hour. The calculated load is 10,430 BTU/hr.
Where that number comes from
San Francisco, CA runs 261 cooling degree days a year, which puts the room at 13 BTU per square foot rather than the 20 BTU/ft² the generic charts use. Applied to this room the rule gives 16,000 BTU/hr.
The winter half of the question
San Francisco, CA designs to 35°F. A mini split is a heat pump, and its heating capacity falls as the outdoor temperature drops — the nameplate is measured at 47°F, not at the temperature you actually need it.
Sizing a single room is not sizing a house
There is no other room to absorb a mistake. An oversized head short-cycles, never runs long enough to dehumidify, and leaves the room cold and damp.
Nearby sizes
- What size mini split does a 800 sq ft bedroom in Indianapolis, IN need?
- What size mini split does a 800 sq ft bedroom in Seattle, WA need?
- What size mini split does a 800 sq ft bedroom in Charlotte, NC need?
- What size mini split does a 800 sq ft bedroom in Denver, CO need?
- What size mini split does a 600 sq ft bedroom in San Francisco, CA need?
- What size mini split does a 800 sq ft living room in San Francisco, CA need?
Read more
- Mini Split Blowing Cold Air in Heat Mode — Defrost, UsuallyEvery air-source heat pump does this. Knowing what a defrost cycle looks like is the difference between waiting ten minutes and calling somebody out.
- Mini Split Leaking Water Indoors — Four Causes, One CommonA cooling head makes a couple of litres a day. It leaves through a small pipe with no pump behind it, and that pipe is where nearly every leak starts.
- Multi-Zone Mini Split Not Cooling Every Room — The Minimum Output ProblemThe system is not underpowered. It is oversized for the one room that is calling, and multi-zone units handle that far worse than single-zone ones.