What size mini split does a 800 sq ft bedroom in Rochester, NY need?

800 ft² bedroom in Rochester, NY
15,000BTU/hr
14,868 BTU/hr of load at 18.6 BTU/ft² — the figure for 732 cooling degree days
800 ft² bedroom in Rochester, NY15,000 BTU/hrHead size to buy14,868 BTU/hrCalculated load16,000 BTU/hrWhat the 20 BTU/f…
Head size to buy15,000BTU/hr
Calculated load800 ft² × 18.6 BTU/ft²14,868BTU/hr
BTU per square foot hereinterpolated from Rochester's 732 cooling degree days18.6BTU/ft²
What the 20 BTU/ft² rule givesthe rule overshoots by 7% here16,000BTU/hr
Summer design temperature88°F
Winter design temperaturea mini split heats too — this is the number that decides whether it can carry the room alone0°F
Summer day–night swinga fairly dry climate20°F
Days at or above 90°F8days/yr
Oversize from the size stepwithin the normal step1%

Notes

  • The "20 BTU per square foot" rule is a Midwest number. Rochester runs 732 cooling degree days, which works out to 18.6 BTU/ft² — so for this bedroom the rule overshoots by 7%. A single national figure has to be wrong somewhere, and this is where.
  • Bedroom: the room where oversizing hurts most — quiet, low load, long runtimes wanted.
  • 15,000 BTU/hr sits close to the load, which is where a mini split works best. Inverter equipment is happiest running long and slow at part load; it is the short, hard cycles of an oversized head that leave a room cold and damp.
  • Rochester is fairly dry — summer nights stay within 20°F of the day's high, the signature of humid air. A meaningful share of this head's work is removing moisture, and it only removes moisture while it is running. This is the climate where an oversized head produces a room that reads cold and feels clammy.
  • Do not forget the winter side. Rochester designs to 0°F. That is cold enough that a standard head will have lost a large part of its rated capacity by the time it is needed most — check the manufacturer's capacity table at 0°F, not the nameplate, and look at hyper-heat rated equipment.
  • Where these numbers come from. Greater Rochester International, 7 km from downtown Rochester, daily records 2015–2024. Design temperatures are calibrated against published ASHRAE values at eight airports and land within about 2°F of them.

The short answer

A 800 square foot bedroom in Rochester, NY needs a head of about 15,000 BTU per hour. The calculated load is 14,868 BTU/hr.

Where that number comes from

Rochester, NY runs 732 cooling degree days a year, which puts the room at 18.6 BTU per square foot rather than the 20 BTU/ft² the generic charts use. Applied to this room the rule gives 16,000 BTU/hr.

The winter half of the question

Rochester, NY designs to 0°F. A mini split is a heat pump, and its heating capacity falls as the outdoor temperature drops — the nameplate is measured at 47°F, not at the temperature you actually need it.

Sizing a single room is not sizing a house

There is no other room to absorb a mistake. An oversized head short-cycles, never runs long enough to dehumidify, and leaves the room cold and damp.