What size mini split does a 800 sq ft bedroom in Nampa, ID need?
800 ft² bedroom in Nampa, ID
18,000BTU/hr
17,042 BTU/hr of load at 21.3 BTU/ft² — the figure for 1,213 cooling degree days
| Head size to buy | 18,000BTU/hr |
|---|---|
| Calculated load800 ft² × 21.3 BTU/ft² | 17,042BTU/hr |
| BTU per square foot hereinterpolated from Nampa's 1,213 cooling degree days | 21.3BTU/ft² |
| What the 20 BTU/ft² rule givesthis room needs 7% more than the rule says | 16,000BTU/hr |
| Summer design temperature | 99°F |
| Winter design temperaturea mini split heats too — this is the number that decides whether it can carry the room alone | 10°F |
| Summer day–night swinga dry climate | 29°F |
| Days at or above 90°F | 56days/yr |
| Oversize from the size stepwithin the normal step | 6% |
Notes
- The "20 BTU per square foot" rule is a Midwest number. Nampa runs 1,213 cooling degree days, which works out to 21.3 BTU/ft² — so for this bedroom the rule is 7% short. A single national figure has to be wrong somewhere, and this is where.
- Bedroom: the room where oversizing hurts most — quiet, low load, long runtimes wanted.
- 18,000 BTU/hr sits close to the load, which is where a mini split works best. Inverter equipment is happiest running long and slow at part load; it is the short, hard cycles of an oversized head that leave a room cold and damp.
- Nampa is dry — nights fall 29°F below the afternoon high, which only happens when there is little water in the air. Latent load is small, so nearly all of the head's capacity goes into temperature. A slightly undersized head is forgiving here: it simply runs longer.
- Do not forget the winter side. Nampa designs to 10°F. A cold-climate rated head will hold most of its capacity there, but a standard one will not — ask for the capacity at 10°F in writing.
- Where these numbers come from. Boise Air Terminal, 27 km from downtown Nampa, daily records 2015–2024. Design temperatures are calibrated against published ASHRAE values at eight airports and land within about 2°F of them.
The short answer
A 800 square foot bedroom in Nampa, ID needs a head of about 18,000 BTU per hour. The calculated load is 17,042 BTU/hr.
Where that number comes from
Nampa, ID runs 1,213 cooling degree days a year, which puts the room at 21.3 BTU per square foot rather than the 20 BTU/ft² the generic charts use. Applied to this room the rule gives 16,000 BTU/hr.
The winter half of the question
Nampa, ID designs to 10°F. A mini split is a heat pump, and its heating capacity falls as the outdoor temperature drops — the nameplate is measured at 47°F, not at the temperature you actually need it.
Sizing a single room is not sizing a house
There is no other room to absorb a mistake. An oversized head short-cycles, never runs long enough to dehumidify, and leaves the room cold and damp.
Nearby sizes
- What size mini split does a 800 sq ft bedroom in Edmond, OK need?
- What size mini split does a 800 sq ft bedroom in Trenton, NJ need?
- What size mini split does a 800 sq ft bedroom in Greenville, NC need?
- What size mini split does a 800 sq ft bedroom in Sandy Hills, UT need?
- What size mini split does a 600 sq ft bedroom in Nampa, ID need?
- What size mini split does a 800 sq ft living room in Nampa, ID need?
Read more
- Mini Split Blowing Cold Air in Heat Mode — Defrost, UsuallyEvery air-source heat pump does this. Knowing what a defrost cycle looks like is the difference between waiting ten minutes and calling somebody out.
- Mini Split Leaking Water Indoors — Four Causes, One CommonA cooling head makes a couple of litres a day. It leaves through a small pipe with no pump behind it, and that pipe is where nearly every leak starts.
- Multi-Zone Mini Split Not Cooling Every Room — The Minimum Output ProblemThe system is not underpowered. It is oversized for the one room that is calling, and multi-zone units handle that far worse than single-zone ones.