ZoneBtuBTU per head, per room, per orientation — not one number for the house.

What size mini split does a 800 sq ft bedroom in Miami, FL need?

800 ft² bedroom in Miami, FL
24,000BTU/hr
23,227 BTU/hr of load at 29 BTU/ft² — the figure for 5,105 cooling degree days
800 ft² bedroom in Miami, FL24,000 BTU/hrHead size to buy23,227 BTU/hrCalculated load16,000 BTU/hrWhat the 20 BTU/f…
Head size to buy24,000BTU/hr
Calculated load800 ft² × 29 BTU/ft²23,227BTU/hr
BTU per square foot hereinterpolated from Miami's 5,105 cooling degree days29BTU/ft²
What the 20 BTU/ft² rule givesthis room needs 45% more than the rule says16,000BTU/hr
Summer design temperature94°F
Winter design temperaturea mini split heats too — this is the number that decides whether it can carry the room alone50°F
Summer day–night swinga humid climate13°F
Days at or above 90°F87days/yr
Oversize from the size stepwithin the normal step3%

Notes

  • The "20 BTU per square foot" rule is a Midwest number. Miami runs 5,105 cooling degree days, which works out to 29 BTU/ft² — so for this bedroom the rule is 45% short. A single national figure has to be wrong somewhere, and this is where.
  • Bedroom: the room where oversizing hurts most — quiet, low load, long runtimes wanted.
  • 24,000 BTU/hr sits close to the load, which is where a mini split works best. Inverter equipment is happiest running long and slow at part load; it is the short, hard cycles of an oversized head that leave a room cold and damp.
  • Miami is humid — summer nights stay within 13°F of the day's high, the signature of humid air. A meaningful share of this head's work is removing moisture, and it only removes moisture while it is running. This is the climate where an oversized head produces a room that reads cold and feels clammy.
  • Do not forget the winter side. Miami designs to 50°F. That is mild enough that heating capacity is not the constraint here; size for cooling and the heating follows.
  • Where these numbers come from. Miami International Airport, 12 km from downtown Miami, daily records 2015–2024. Design temperatures are calibrated against published ASHRAE values at eight airports and land within about 2°F of them.

The short answer

A 800 square foot bedroom in Miami, FL needs a head of about 24,000 BTU per hour. The calculated load is 23,227 BTU/hr.

Where that number comes from

Miami, FL runs 5,105 cooling degree days a year, which puts the room at 29 BTU per square foot rather than the 20 BTU/ft² the generic charts use. Applied to this room the rule gives 16,000 BTU/hr.

The winter half of the question

Miami, FL designs to 50°F. A mini split is a heat pump, and its heating capacity falls as the outdoor temperature drops — the nameplate is measured at 47°F, not at the temperature you actually need it.

Sizing a single room is not sizing a house

There is no other room to absorb a mistake. An oversized head short-cycles, never runs long enough to dehumidify, and leaves the room cold and damp.

Nearby sizes