What size mini split does a 800 sq ft bedroom in Green Bay, WI need?

800 ft² bedroom in Green Bay, WI
15,000BTU/hr
13,911 BTU/hr of load at 17.4 BTU/ft² — the figure for 586 cooling degree days
800 ft² bedroom in Green Bay, WI15,000 BTU/hrHead size to buy13,911 BTU/hrCalculated load16,000 BTU/hrWhat the 20 BTU/f…
Head size to buy15,000BTU/hr
Calculated load800 ft² × 17.4 BTU/ft²13,911BTU/hr
BTU per square foot hereinterpolated from Green Bay's 586 cooling degree days17.4BTU/ft²
What the 20 BTU/ft² rule givesthe rule overshoots by 13% here16,000BTU/hr
Summer design temperature87°F
Winter design temperaturea mini split heats too — this is the number that decides whether it can carry the room alone-8°F
Summer day–night swinga fairly dry climate21°F
Days at or above 90°F4days/yr
Oversize from the size stepwithin the normal step8%

Notes

  • The "20 BTU per square foot" rule is a Midwest number. Green Bay runs 586 cooling degree days, which works out to 17.4 BTU/ft² — so for this bedroom the rule overshoots by 13%. A single national figure has to be wrong somewhere, and this is where.
  • Bedroom: the room where oversizing hurts most — quiet, low load, long runtimes wanted.
  • 15,000 BTU/hr sits close to the load, which is where a mini split works best. Inverter equipment is happiest running long and slow at part load; it is the short, hard cycles of an oversized head that leave a room cold and damp.
  • Green Bay is fairly dry — summer nights stay within 21°F of the day's high, the signature of humid air. A meaningful share of this head's work is removing moisture, and it only removes moisture while it is running. This is the climate where an oversized head produces a room that reads cold and feels clammy.
  • Do not forget the winter side. Green Bay designs to -8°F. That is cold enough that a standard head will have lost a large part of its rated capacity by the time it is needed most — check the manufacturer's capacity table at -8°F, not the nameplate, and look at hyper-heat rated equipment.
  • Where these numbers come from. Austin Straubel International Airport, 10 km from downtown Green Bay, daily records 2015–2024. Design temperatures are calibrated against published ASHRAE values at eight airports and land within about 2°F of them.

The short answer

A 800 square foot bedroom in Green Bay, WI needs a head of about 15,000 BTU per hour. The calculated load is 13,911 BTU/hr.

Where that number comes from

Green Bay, WI runs 586 cooling degree days a year, which puts the room at 17.4 BTU per square foot rather than the 20 BTU/ft² the generic charts use. Applied to this room the rule gives 16,000 BTU/hr.

The winter half of the question

Green Bay, WI designs to -8°F. A mini split is a heat pump, and its heating capacity falls as the outdoor temperature drops — the nameplate is measured at 47°F, not at the temperature you actually need it.

Sizing a single room is not sizing a house

There is no other room to absorb a mistake. An oversized head short-cycles, never runs long enough to dehumidify, and leaves the room cold and damp.