ZoneBtuBTU per head, per room, per orientation — not one number for the house.

What size mini split does a 800 sq ft bedroom in Ankeny, IA need?

800 ft² bedroom in Ankeny, IA
18,000BTU/hr
17,253 BTU/hr of load at 21.6 BTU/ft² — the figure for 1,274 cooling degree days
800 ft² bedroom in Ankeny, IA18,000 BTU/hrHead size to buy17,253 BTU/hrCalculated load16,000 BTU/hrWhat the 20 BTU/f…
Head size to buy18,000BTU/hr
Calculated load800 ft² × 21.6 BTU/ft²17,253BTU/hr
BTU per square foot hereinterpolated from Ankeny's 1,274 cooling degree days21.6BTU/ft²
What the 20 BTU/ft² rule givesthis room needs 8% more than the rule says16,000BTU/hr
Summer design temperature92°F
Winter design temperaturea mini split heats too — this is the number that decides whether it can carry the room alone-6°F
Summer day–night swinga fairly dry climate20°F
Days at or above 90°F22days/yr
Oversize from the size stepwithin the normal step4%

Notes

  • The "20 BTU per square foot" rule is a Midwest number. Ankeny runs 1,274 cooling degree days, which works out to 21.6 BTU/ft² — so for this bedroom the rule is 8% short. A single national figure has to be wrong somewhere, and this is where.
  • Bedroom: the room where oversizing hurts most — quiet, low load, long runtimes wanted.
  • 18,000 BTU/hr sits close to the load, which is where a mini split works best. Inverter equipment is happiest running long and slow at part load; it is the short, hard cycles of an oversized head that leave a room cold and damp.
  • Ankeny is fairly dry — summer nights stay within 20°F of the day's high, the signature of humid air. A meaningful share of this head's work is removing moisture, and it only removes moisture while it is running. This is the climate where an oversized head produces a room that reads cold and feels clammy.
  • Do not forget the winter side. Ankeny designs to -6°F. That is cold enough that a standard head will have lost a large part of its rated capacity by the time it is needed most — check the manufacturer's capacity table at -6°F, not the nameplate, and look at hyper-heat rated equipment.
  • Where these numbers come from. Des Moines International, 22 km from downtown Ankeny, daily records 2015–2024. Design temperatures are calibrated against published ASHRAE values at eight airports and land within about 2°F of them.

The short answer

A 800 square foot bedroom in Ankeny, IA needs a head of about 18,000 BTU per hour. The calculated load is 17,253 BTU/hr.

Where that number comes from

Ankeny, IA runs 1,274 cooling degree days a year, which puts the room at 21.6 BTU per square foot rather than the 20 BTU/ft² the generic charts use. Applied to this room the rule gives 16,000 BTU/hr.

The winter half of the question

Ankeny, IA designs to -6°F. A mini split is a heat pump, and its heating capacity falls as the outdoor temperature drops — the nameplate is measured at 47°F, not at the temperature you actually need it.

Sizing a single room is not sizing a house

There is no other room to absorb a mistake. An oversized head short-cycles, never runs long enough to dehumidify, and leaves the room cold and damp.

Nearby sizes