ZoneBtuBTU per head, per room, per orientation — not one number for the house.

What size mini split does a 600 sq ft living room in Terre Haute, IN need?

600 ft² living room in Terre Haute, IN
9,000BTU/hr
7,659 BTU/hr of load at 11.6 BTU/ft² — the figure for 200 cooling degree days
600 ft² living room in Terre Haute, IN9,000 BTU/hrHead size to buy7,659 BTU/hrCalculated load13,200 BTU/hrWhat the 20 BTU/f…
Head size to buy9,000BTU/hr
Calculated load600 ft² × 11.6 BTU/ft² × 1.1 for a living room7,659BTU/hr
BTU per square foot hereinterpolated from Terre Haute's 200 cooling degree days11.6BTU/ft²
What the 20 BTU/ft² rule givesthe rule overshoots by 42% here13,200BTU/hr
Summer design temperature79°F
Winter design temperaturea mini split heats too — this is the number that decides whether it can carry the room alone-2°F
Summer day–night swinga moderately humid climate18°F
Days at or above 90°F0days/yr
Oversize from the size stepwithin the normal step18%

Notes

  • The "20 BTU per square foot" rule is a Midwest number. Terre Haute runs 200 cooling degree days, which works out to 11.6 BTU/ft² — so for this living room the rule overshoots by 42%. A single national figure has to be wrong somewhere, and this is where.
  • Living room: more people, more glazing, more electronics. The 1.1× factor accounts for that.
  • 9,000 BTU/hr sits close to the load, which is where a mini split works best. Inverter equipment is happiest running long and slow at part load; it is the short, hard cycles of an oversized head that leave a room cold and damp.
  • Terre Haute is moderately humid — summer nights stay within 18°F of the day's high, the signature of humid air. A meaningful share of this head's work is removing moisture, and it only removes moisture while it is running. This is the climate where an oversized head produces a room that reads cold and feels clammy.
  • Do not forget the winter side. Terre Haute designs to -2°F. That is cold enough that a standard head will have lost a large part of its rated capacity by the time it is needed most — check the manufacturer's capacity table at -2°F, not the nameplate, and look at hyper-heat rated equipment.
  • Where these numbers come from. Terre Haute / Swalls, 9 km from downtown Terre Haute, daily records 2015–2024. Design temperatures are calibrated against published ASHRAE values at eight airports and land within about 2°F of them.

The short answer

A 600 square foot living room in Terre Haute, IN needs a head of about 9,000 BTU per hour. The calculated load is 7,659 BTU/hr.

Where that number comes from

Terre Haute, IN runs 200 cooling degree days a year, which puts the room at 11.6 BTU per square foot rather than the 20 BTU/ft² the generic charts use. Applied to this room the rule gives 13,200 BTU/hr.

The winter half of the question

Terre Haute, IN designs to -2°F. A mini split is a heat pump, and its heating capacity falls as the outdoor temperature drops — the nameplate is measured at 47°F, not at the temperature you actually need it.

Sizing a single room is not sizing a house

There is no other room to absorb a mistake. An oversized head short-cycles, never runs long enough to dehumidify, and leaves the room cold and damp.

Nearby sizes

Read more