ZoneBtuBTU per head, per room, per orientation — not one number for the house.

What size mini split does a 600 sq ft living room in Lexington-Fayette, KY need?

600 ft² living room in Lexington-Fayette, KY
15,000BTU/hr
14,614 BTU/hr of load at 22.1 BTU/ft² — the figure for 1,418 cooling degree days
600 ft² living room in Lexington-Fayette, KY15,000 BTU/hrHead size to buy14,614 BTU/hrCalculated load13,200 BTU/hrWhat the 20 BTU/f…
Head size to buy15,000BTU/hr
Calculated load600 ft² × 22.1 BTU/ft² × 1.1 for a living room14,614BTU/hr
BTU per square foot hereinterpolated from Lexington-Fayette's 1,418 cooling degree days22.1BTU/ft²
What the 20 BTU/ft² rule givesthis room needs 11% more than the rule says13,200BTU/hr
Summer design temperature92°F
Winter design temperaturea mini split heats too — this is the number that decides whether it can carry the room alone6°F
Summer day–night swinga fairly dry climate20°F
Days at or above 90°F23days/yr
Oversize from the size stepwithin the normal step3%

Notes

  • The "20 BTU per square foot" rule is a Midwest number. Lexington-Fayette runs 1,418 cooling degree days, which works out to 22.1 BTU/ft² — so for this living room the rule is 11% short. A single national figure has to be wrong somewhere, and this is where.
  • Living room: more people, more glazing, more electronics. The 1.1× factor accounts for that.
  • 15,000 BTU/hr sits close to the load, which is where a mini split works best. Inverter equipment is happiest running long and slow at part load; it is the short, hard cycles of an oversized head that leave a room cold and damp.
  • Lexington-Fayette is fairly dry — summer nights stay within 20°F of the day's high, the signature of humid air. A meaningful share of this head's work is removing moisture, and it only removes moisture while it is running. This is the climate where an oversized head produces a room that reads cold and feels clammy.
  • Do not forget the winter side. Lexington-Fayette designs to 6°F. A cold-climate rated head will hold most of its capacity there, but a standard one will not — ask for the capacity at 6°F in writing.
  • Where these numbers come from. Lexington Blue Grass Airport, 13 km from downtown Lexington-Fayette, daily records 2015–2024. Design temperatures are calibrated against published ASHRAE values at eight airports and land within about 2°F of them.

The short answer

A 600 square foot living room in Lexington-Fayette, KY needs a head of about 15,000 BTU per hour. The calculated load is 14,614 BTU/hr.

Where that number comes from

Lexington-Fayette, KY runs 1,418 cooling degree days a year, which puts the room at 22.1 BTU per square foot rather than the 20 BTU/ft² the generic charts use. Applied to this room the rule gives 13,200 BTU/hr.

The winter half of the question

Lexington-Fayette, KY designs to 6°F. A mini split is a heat pump, and its heating capacity falls as the outdoor temperature drops — the nameplate is measured at 47°F, not at the temperature you actually need it.

Sizing a single room is not sizing a house

There is no other room to absorb a mistake. An oversized head short-cycles, never runs long enough to dehumidify, and leaves the room cold and damp.

Nearby sizes