ZoneBtuBTU per head, per room, per orientation — not one number for the house.

What size mini split does a 600 sq ft bedroom in Minot, ND need?

600 ft² bedroom in Minot, ND
12,000BTU/hr
10,851 BTU/hr of load at 18.1 BTU/ft² — the figure for 667 cooling degree days
600 ft² bedroom in Minot, ND12,000 BTU/hrHead size to buy10,851 BTU/hrCalculated load12,000 BTU/hrWhat the 20 BTU/f…
Head size to buy12,000BTU/hr
Calculated load600 ft² × 18.1 BTU/ft²10,851BTU/hr
BTU per square foot hereinterpolated from Minot's 667 cooling degree days18.1BTU/ft²
What the 20 BTU/ft² rule givesthe rule overshoots by 10% here12,000BTU/hr
Summer design temperature93°F
Winter design temperaturea mini split heats too — this is the number that decides whether it can carry the room alone-21°F
Summer day–night swinga dry climate27°F
Days at or above 90°F21days/yr
Oversize from the size stepwithin the normal step11%

Notes

  • The "20 BTU per square foot" rule is a Midwest number. Minot runs 667 cooling degree days, which works out to 18.1 BTU/ft² — so for this bedroom the rule overshoots by 10%. A single national figure has to be wrong somewhere, and this is where.
  • Bedroom: the room where oversizing hurts most — quiet, low load, long runtimes wanted.
  • 12,000 BTU/hr sits close to the load, which is where a mini split works best. Inverter equipment is happiest running long and slow at part load; it is the short, hard cycles of an oversized head that leave a room cold and damp.
  • Minot is dry — nights fall 27°F below the afternoon high, which only happens when there is little water in the air. Latent load is small, so nearly all of the head's capacity goes into temperature. A slightly undersized head is forgiving here: it simply runs longer.
  • Do not forget the winter side. Minot designs to -21°F. That is cold enough that a standard head will have lost a large part of its rated capacity by the time it is needed most — check the manufacturer's capacity table at -21°F, not the nameplate, and look at hyper-heat rated equipment.
  • Where these numbers come from. Bismarck Municipal Airport, 166 km from downtown Minot, daily records 2015–2024. Design temperatures are calibrated against published ASHRAE values at eight airports and land within about 2°F of them.

The short answer

A 600 square foot bedroom in Minot, ND needs a head of about 12,000 BTU per hour. The calculated load is 10,851 BTU/hr.

Where that number comes from

Minot, ND runs 667 cooling degree days a year, which puts the room at 18.1 BTU per square foot rather than the 20 BTU/ft² the generic charts use. Applied to this room the rule gives 12,000 BTU/hr.

The winter half of the question

Minot, ND designs to -21°F. A mini split is a heat pump, and its heating capacity falls as the outdoor temperature drops — the nameplate is measured at 47°F, not at the temperature you actually need it.

Sizing a single room is not sizing a house

There is no other room to absorb a mistake. An oversized head short-cycles, never runs long enough to dehumidify, and leaves the room cold and damp.