What size mini split does a 600 sq ft bedroom in Bossier City, LA need?
600 ft² bedroom in Bossier City, LA
18,000BTU/hr
15,688 BTU/hr of load at 26.1 BTU/ft² — the figure for 2,985 cooling degree days
| Head size to buy | 18,000BTU/hr |
|---|---|
| Calculated load600 ft² × 26.1 BTU/ft² | 15,688BTU/hr |
| BTU per square foot hereinterpolated from Bossier City's 2,985 cooling degree days | 26.1BTU/ft² |
| What the 20 BTU/ft² rule givesthis room needs 31% more than the rule says | 12,000BTU/hr |
| Summer design temperature | 99°F |
| Winter design temperaturea mini split heats too — this is the number that decides whether it can carry the room alone | 24°F |
| Summer day–night swinga fairly dry climate | 20°F |
| Days at or above 90°F | 103days/yr |
| Oversize from the size stepwithin the normal step | 15% |
Notes
- The "20 BTU per square foot" rule is a Midwest number. Bossier City runs 2,985 cooling degree days, which works out to 26.1 BTU/ft² — so for this bedroom the rule is 31% short. A single national figure has to be wrong somewhere, and this is where.
- Bedroom: the room where oversizing hurts most — quiet, low load, long runtimes wanted.
- 18,000 BTU/hr sits close to the load, which is where a mini split works best. Inverter equipment is happiest running long and slow at part load; it is the short, hard cycles of an oversized head that leave a room cold and damp.
- Bossier City is fairly dry — summer nights stay within 20°F of the day's high, the signature of humid air. A meaningful share of this head's work is removing moisture, and it only removes moisture while it is running. This is the climate where an oversized head produces a room that reads cold and feels clammy.
- Do not forget the winter side. Bossier City designs to 24°F. A cold-climate rated head will hold most of its capacity there, but a standard one will not — ask for the capacity at 24°F in writing.
- Where these numbers come from. Shreveport Regional Airport, 69 km from downtown Bossier City, daily records 2015–2024. Design temperatures are calibrated against published ASHRAE values at eight airports and land within about 2°F of them.
The short answer
A 600 square foot bedroom in Bossier City, LA needs a head of about 18,000 BTU per hour. The calculated load is 15,688 BTU/hr.
Where that number comes from
Bossier City, LA runs 2,985 cooling degree days a year, which puts the room at 26.1 BTU per square foot rather than the 20 BTU/ft² the generic charts use. Applied to this room the rule gives 12,000 BTU/hr.
The winter half of the question
Bossier City, LA designs to 24°F. A mini split is a heat pump, and its heating capacity falls as the outdoor temperature drops — the nameplate is measured at 47°F, not at the temperature you actually need it.
Sizing a single room is not sizing a house
There is no other room to absorb a mistake. An oversized head short-cycles, never runs long enough to dehumidify, and leaves the room cold and damp.
Nearby sizes
- What size mini split does a 600 sq ft bedroom in Maple Grove, MN need?
- What size mini split does a 600 sq ft bedroom in Woodbury, MN need?
- What size mini split does a 600 sq ft bedroom in Waterloo, IA need?
- What size mini split does a 600 sq ft bedroom in Eau Claire, WI need?
- What size mini split does a 500 sq ft bedroom in Bossier City, LA need?
- What size mini split does a 800 sq ft bedroom in Bossier City, LA need?
- What size mini split does a 600 sq ft living room in Bossier City, LA need?
Read more
- Mini Split Blowing Cold Air in Heat Mode — Defrost, UsuallyEvery air-source heat pump does this. Knowing what a defrost cycle looks like is the difference between waiting ten minutes and calling somebody out.
- Mini Split Leaking Water Indoors — Four Causes, One CommonA cooling head makes a couple of litres a day. It leaves through a small pipe with no pump behind it, and that pipe is where nearly every leak starts.
- Multi-Zone Mini Split Not Cooling Every Room — The Minimum Output ProblemThe system is not underpowered. It is oversized for the one room that is calling, and multi-zone units handle that far worse than single-zone ones.