ZoneBtuBTU per head, per room, per orientation — not one number for the house.

What size mini split does a 500 sq ft bedroom in Burlington, VT need?

500 ft² bedroom in Burlington, VT
12,000BTU/hr
9,397 BTU/hr of load at 18.8 BTU/ft² — the figure for 761 cooling degree days
500 ft² bedroom in Burlington, VT12,000 BTU/hrHead size to buy9,397 BTU/hrCalculated load10,000 BTU/hrWhat the 20 BTU/f…
Head size to buy12,000BTU/hr
Calculated load500 ft² × 18.8 BTU/ft²9,397BTU/hr
BTU per square foot hereinterpolated from Burlington's 761 cooling degree days18.8BTU/ft²
What the 20 BTU/ft² rule givesthe rule overshoots by 6% here10,000BTU/hr
Summer design temperature89°F
Winter design temperaturea mini split heats too — this is the number that decides whether it can carry the room alone-8°F
Summer day–night swinga fairly dry climate20°F
Days at or above 90°F9days/yr
Oversize from the size stepa big step — read the note28%

Notes

  • The "20 BTU per square foot" rule is a Midwest number. Burlington runs 761 cooling degree days, which works out to 18.8 BTU/ft² — so for this bedroom the rule overshoots by 6%. A single national figure has to be wrong somewhere, and this is where.
  • Bedroom: the room where oversizing hurts most — quiet, low load, long runtimes wanted.
  • 12,000 BTU/hr is 28% above the load, and the gap between head sizes is wide — the next size down is 9,000. In a single room that matters more than it would on a central system: there are no other rooms to absorb the excess capacity. If the room is well insulated and shaded, the smaller head is usually the better buy, and modern inverter compressors modulate down far better than they modulate up.
  • Burlington is fairly dry — summer nights stay within 20°F of the day's high, the signature of humid air. A meaningful share of this head's work is removing moisture, and it only removes moisture while it is running. This is the climate where an oversized head produces a room that reads cold and feels clammy.
  • Do not forget the winter side. Burlington designs to -8°F. That is cold enough that a standard head will have lost a large part of its rated capacity by the time it is needed most — check the manufacturer's capacity table at -8°F, not the nameplate, and look at hyper-heat rated equipment.
  • Where these numbers come from. Burlington International, 5 km from downtown Burlington, daily records 2015–2024. Design temperatures are calibrated against published ASHRAE values at eight airports and land within about 2°F of them.

The short answer

A 500 square foot bedroom in Burlington, VT needs a head of about 12,000 BTU per hour. The calculated load is 9,397 BTU/hr.

Where that number comes from

Burlington, VT runs 761 cooling degree days a year, which puts the room at 18.8 BTU per square foot rather than the 20 BTU/ft² the generic charts use. Applied to this room the rule gives 10,000 BTU/hr.

The winter half of the question

Burlington, VT designs to -8°F. A mini split is a heat pump, and its heating capacity falls as the outdoor temperature drops — the nameplate is measured at 47°F, not at the temperature you actually need it.

Sizing a single room is not sizing a house

There is no other room to absorb a mistake. An oversized head short-cycles, never runs long enough to dehumidify, and leaves the room cold and damp.