ZoneBtuBTU per head, per room, per orientation — not one number for the house.

What size mini split does a 400 sq ft bedroom in Oakland, CA need?

400 ft² bedroom in Oakland, CA
6,000BTU/hr
5,215 BTU/hr of load at 13 BTU/ft² — the figure for 261 cooling degree days
400 ft² bedroom in Oakland, CA6,000 BTU/hrHead size to buy5,215 BTU/hrCalculated load8,000 BTU/hrWhat the 20 BTU/f…
Head size to buy6,000BTU/hr
Calculated load400 ft² × 13 BTU/ft²5,215BTU/hr
BTU per square foot hereinterpolated from Oakland's 261 cooling degree days13BTU/ft²
What the 20 BTU/ft² rule givesthe rule overshoots by 35% here8,000BTU/hr
Summer design temperature85°F
Winter design temperaturea mini split heats too — this is the number that decides whether it can carry the room alone35°F
Summer day–night swinga moderately humid climate16°F
Days at or above 90°F6days/yr
Oversize from the size stepwithin the normal step15%

Notes

  • The "20 BTU per square foot" rule is a Midwest number. Oakland runs 261 cooling degree days, which works out to 13 BTU/ft² — so for this bedroom the rule overshoots by 35%. A single national figure has to be wrong somewhere, and this is where.
  • Bedroom: the room where oversizing hurts most — quiet, low load, long runtimes wanted.
  • 6,000 BTU/hr sits close to the load, which is where a mini split works best. Inverter equipment is happiest running long and slow at part load; it is the short, hard cycles of an oversized head that leave a room cold and damp.
  • Oakland is moderately humid — summer nights stay within 16°F of the day's high, the signature of humid air. A meaningful share of this head's work is removing moisture, and it only removes moisture while it is running. This is the climate where an oversized head produces a room that reads cold and feels clammy.
  • Do not forget the winter side. Oakland designs to 35°F. That is mild enough that heating capacity is not the constraint here; size for cooling and the heating follows.
  • Where these numbers come from. Metro Oakland International Airport, 10 km from downtown Oakland, daily records 2015–2024. Design temperatures are calibrated against published ASHRAE values at eight airports and land within about 2°F of them.

The short answer

A 400 square foot bedroom in Oakland, CA needs a head of about 6,000 BTU per hour. The calculated load is 5,215 BTU/hr.

Where that number comes from

Oakland, CA runs 261 cooling degree days a year, which puts the room at 13 BTU per square foot rather than the 20 BTU/ft² the generic charts use. Applied to this room the rule gives 8,000 BTU/hr.

The winter half of the question

Oakland, CA designs to 35°F. A mini split is a heat pump, and its heating capacity falls as the outdoor temperature drops — the nameplate is measured at 47°F, not at the temperature you actually need it.

Sizing a single room is not sizing a house

There is no other room to absorb a mistake. An oversized head short-cycles, never runs long enough to dehumidify, and leaves the room cold and damp.