ZoneBtuBTU per head, per room, per orientation — not one number for the house.

What size mini split does a 400 sq ft bedroom in Cranston, RI need?

400 ft² bedroom in Cranston, RI
9,000BTU/hr
7,905 BTU/hr of load at 19.8 BTU/ft² — the figure for 911 cooling degree days
400 ft² bedroom in Cranston, RI9,000 BTU/hrHead size to buy7,905 BTU/hrCalculated load8,000 BTU/hrWhat the 20 BTU/f…
Head size to buy9,000BTU/hr
Calculated load400 ft² × 19.8 BTU/ft²7,905BTU/hr
BTU per square foot hereinterpolated from Cranston's 911 cooling degree days19.8BTU/ft²
What the 20 BTU/ft² rule givesthe rule overshoots by 1% here8,000BTU/hr
Summer design temperature89°F
Winter design temperaturea mini split heats too — this is the number that decides whether it can carry the room alone7°F
Summer day–night swinga moderately humid climate18°F
Days at or above 90°F10days/yr
Oversize from the size stepwithin the normal step14%

Notes

  • The "20 BTU per square foot" rule is a Midwest number. Cranston runs 911 cooling degree days, which works out to 19.8 BTU/ft² — so for this bedroom the rule overshoots by 1%. A single national figure has to be wrong somewhere, and this is where.
  • Bedroom: the room where oversizing hurts most — quiet, low load, long runtimes wanted.
  • 9,000 BTU/hr sits close to the load, which is where a mini split works best. Inverter equipment is happiest running long and slow at part load; it is the short, hard cycles of an oversized head that leave a room cold and damp.
  • Cranston is moderately humid — summer nights stay within 18°F of the day's high, the signature of humid air. A meaningful share of this head's work is removing moisture, and it only removes moisture while it is running. This is the climate where an oversized head produces a room that reads cold and feels clammy.
  • Do not forget the winter side. Cranston designs to 7°F. A cold-climate rated head will hold most of its capacity there, but a standard one will not — ask for the capacity at 7°F in writing.
  • Where these numbers come from. Providence Green State Airport, 5 km from downtown Cranston, daily records 2015–2024. Design temperatures are calibrated against published ASHRAE values at eight airports and land within about 2°F of them.

The short answer

A 400 square foot bedroom in Cranston, RI needs a head of about 9,000 BTU per hour. The calculated load is 7,905 BTU/hr.

Where that number comes from

Cranston, RI runs 911 cooling degree days a year, which puts the room at 19.8 BTU per square foot rather than the 20 BTU/ft² the generic charts use. Applied to this room the rule gives 8,000 BTU/hr.

The winter half of the question

Cranston, RI designs to 7°F. A mini split is a heat pump, and its heating capacity falls as the outdoor temperature drops — the nameplate is measured at 47°F, not at the temperature you actually need it.

Sizing a single room is not sizing a house

There is no other room to absorb a mistake. An oversized head short-cycles, never runs long enough to dehumidify, and leaves the room cold and damp.