What size mini split does a 200 sq ft living room in Phenix City, AL need?

200 ft² living room in Phenix City, AL
6,000BTU/hr
5,462 BTU/hr of load at 24.8 BTU/ft² — the figure for 2,336 cooling degree days
200 ft² living room in Phenix City, AL6,000 BTU/hrHead size to buy5,462 BTU/hrCalculated load4,400 BTU/hrWhat the 20 BTU/f…
Head size to buy6,000BTU/hr
Calculated load200 ft² × 24.8 BTU/ft² × 1.1 for a living room5,462BTU/hr
BTU per square foot hereinterpolated from Phenix City's 2,336 cooling degree days24.8BTU/ft²
What the 20 BTU/ft² rule givesthis room needs 24% more than the rule says4,400BTU/hr
Summer design temperature97°F
Winter design temperaturea mini split heats too — this is the number that decides whether it can carry the room alone20°F
Summer day–night swinga fairly dry climate24°F
Days at or above 90°F96days/yr
Oversize from the size stepwithin the normal step10%

Notes

  • The "20 BTU per square foot" rule is a Midwest number. Phenix City runs 2,336 cooling degree days, which works out to 24.8 BTU/ft² — so for this living room the rule is 24% short. A single national figure has to be wrong somewhere, and this is where.
  • Living room: more people, more glazing, more electronics. The 1.1× factor accounts for that.
  • 6,000 BTU/hr sits close to the load, which is where a mini split works best. Inverter equipment is happiest running long and slow at part load; it is the short, hard cycles of an oversized head that leave a room cold and damp.
  • Phenix City is dry — nights fall 24°F below the afternoon high, which only happens when there is little water in the air. Latent load is small, so nearly all of the head's capacity goes into temperature. A slightly undersized head is forgiving here: it simply runs longer.
  • Do not forget the winter side. Phenix City designs to 20°F. A cold-climate rated head will hold most of its capacity there, but a standard one will not — ask for the capacity at 20°F in writing.
  • Where these numbers come from. Fort Benning, 22 km from downtown Phenix City, daily records 2015–2024. Design temperatures are calibrated against published ASHRAE values at eight airports and land within about 2°F of them.

The short answer

A 200 square foot living room in Phenix City, AL needs a head of about 6,000 BTU per hour. The calculated load is 5,462 BTU/hr.

Where that number comes from

Phenix City, AL runs 2,336 cooling degree days a year, which puts the room at 24.8 BTU per square foot rather than the 20 BTU/ft² the generic charts use. Applied to this room the rule gives 4,400 BTU/hr.

The winter half of the question

Phenix City, AL designs to 20°F. A mini split is a heat pump, and its heating capacity falls as the outdoor temperature drops — the nameplate is measured at 47°F, not at the temperature you actually need it.

Sizing a single room is not sizing a house