What size mini split does a 200 sq ft living room in Juneau, AK need?
200 ft² living room in Juneau, AK
6,000BTU/hr
2,200 BTU/hr of load at 10 BTU/ft² — the figure for 9 cooling degree days
| Head size to buy | 6,000BTU/hr |
|---|---|
| Calculated load200 ft² × 10 BTU/ft² × 1.1 for a living room | 2,200BTU/hr |
| BTU per square foot hereinterpolated from Juneau's 9 cooling degree days | 10BTU/ft² |
| What the 20 BTU/ft² rule givesthe rule overshoots by 50% here | 4,400BTU/hr |
| Summer design temperature | 73°F |
| Winter design temperaturea mini split heats too — this is the number that decides whether it can carry the room alone | 6°F |
| Summer day–night swinga humid climate | 14°F |
| Days at or above 90°F | 0days/yr |
| Oversize from the size stepa big step — read the note | 173% |
Notes
- The "20 BTU per square foot" rule is a Midwest number. Juneau runs 9 cooling degree days, which works out to 10 BTU/ft² — so for this living room the rule overshoots by 50%. A single national figure has to be wrong somewhere, and this is where.
- Living room: more people, more glazing, more electronics. The 1.1× factor accounts for that.
- 6,000 BTU/hr is 173% above the load, and the gap between head sizes is wide — this is already the smallest head. In a single room that matters more than it would on a central system: there are no other rooms to absorb the excess capacity. If the room is well insulated and shaded, the smaller head is usually the better buy, and modern inverter compressors modulate down far better than they modulate up.
- Juneau is humid — summer nights stay within 14°F of the day's high, the signature of humid air. A meaningful share of this head's work is removing moisture, and it only removes moisture while it is running. This is the climate where an oversized head produces a room that reads cold and feels clammy.
- Do not forget the winter side. Juneau designs to 6°F. A cold-climate rated head will hold most of its capacity there, but a standard one will not — ask for the capacity at 6°F in writing.
- Where these numbers come from. Juneau International Airport, 10 km from downtown Juneau, daily records 2015–2024. Design temperatures are calibrated against published ASHRAE values at eight airports and land within about 2°F of them.
The short answer
A 200 square foot living room in Juneau, AK needs a head of about 6,000 BTU per hour. The calculated load is 2,200 BTU/hr.
Where that number comes from
Juneau, AK runs 9 cooling degree days a year, which puts the room at 10 BTU per square foot rather than the 20 BTU/ft² the generic charts use. Applied to this room the rule gives 4,400 BTU/hr.
The winter half of the question
Juneau, AK designs to 6°F. A mini split is a heat pump, and its heating capacity falls as the outdoor temperature drops — the nameplate is measured at 47°F, not at the temperature you actually need it.
Sizing a single room is not sizing a house
There is no other room to absorb a mistake. An oversized head short-cycles, never runs long enough to dehumidify, and leaves the room cold and damp.
Nearby sizes
Read more
- Mini Split Blowing Cold Air in Heat Mode — Defrost, UsuallyEvery air-source heat pump does this. Knowing what a defrost cycle looks like is the difference between waiting ten minutes and calling somebody out.
- Mini Split Leaking Water Indoors — Four Causes, One CommonA cooling head makes a couple of litres a day. It leaves through a small pipe with no pump behind it, and that pipe is where nearly every leak starts.
- Multi-Zone Mini Split Not Cooling Every Room — The Minimum Output ProblemThe system is not underpowered. It is oversized for the one room that is calling, and multi-zone units handle that far worse than single-zone ones.