ZoneBtuBTU per head, per room, per orientation — not one number for the house.

What size mini split does a 200 sq ft bedroom in Spring Valley, NV need?

200 ft² bedroom in Spring Valley, NV
6,000BTU/hr
5,546 BTU/hr of load at 27.7 BTU/ft² — the figure for 4,007 cooling degree days
200 ft² bedroom in Spring Valley, NV6,000 BTU/hrHead size to buy5,546 BTU/hrCalculated load4,000 BTU/hrWhat the 20 BTU/f…
Head size to buy6,000BTU/hr
Calculated load200 ft² × 27.7 BTU/ft²5,546BTU/hr
BTU per square foot hereinterpolated from Spring Valley's 4,007 cooling degree days27.7BTU/ft²
What the 20 BTU/ft² rule givesthis room needs 39% more than the rule says4,000BTU/hr
Summer design temperature110°F
Winter design temperaturea mini split heats too — this is the number that decides whether it can carry the room alone32°F
Summer day–night swinga fairly dry climate23°F
Days at or above 90°F136days/yr
Oversize from the size stepwithin the normal step8%

Notes

  • The "20 BTU per square foot" rule is a Midwest number. Spring Valley runs 4,007 cooling degree days, which works out to 27.7 BTU/ft² — so for this bedroom the rule is 39% short. A single national figure has to be wrong somewhere, and this is where.
  • Bedroom: the room where oversizing hurts most — quiet, low load, long runtimes wanted.
  • 6,000 BTU/hr sits close to the load, which is where a mini split works best. Inverter equipment is happiest running long and slow at part load; it is the short, hard cycles of an oversized head that leave a room cold and damp.
  • Spring Valley is dry — nights fall 23°F below the afternoon high, which only happens when there is little water in the air. Latent load is small, so nearly all of the head's capacity goes into temperature. A slightly undersized head is forgiving here: it simply runs longer.
  • Do not forget the winter side. Spring Valley designs to 32°F. That is mild enough that heating capacity is not the constraint here; size for cooling and the heating follows.
  • Where these numbers come from. McCarran International Airport, 2 km from downtown Spring Valley, daily records 2015–2024. Design temperatures are calibrated against published ASHRAE values at eight airports and land within about 2°F of them.

The short answer

A 200 square foot bedroom in Spring Valley, NV needs a head of about 6,000 BTU per hour. The calculated load is 5,546 BTU/hr.

Where that number comes from

Spring Valley, NV runs 4,007 cooling degree days a year, which puts the room at 27.7 BTU per square foot rather than the 20 BTU/ft² the generic charts use. Applied to this room the rule gives 4,000 BTU/hr.

The winter half of the question

Spring Valley, NV designs to 32°F. A mini split is a heat pump, and its heating capacity falls as the outdoor temperature drops — the nameplate is measured at 47°F, not at the temperature you actually need it.

Sizing a single room is not sizing a house

There is no other room to absorb a mistake. An oversized head short-cycles, never runs long enough to dehumidify, and leaves the room cold and damp.

Nearby sizes

Read more