What size mini split does a 200 sq ft bedroom in Norfolk, VA need?

200 ft² bedroom in Norfolk, VA
6,000BTU/hr
4,790 BTU/hr of load at 23.9 BTU/ft² — the figure for 1,984 cooling degree days
200 ft² bedroom in Norfolk, VA6,000 BTU/hrHead size to buy4,790 BTU/hrCalculated load4,000 BTU/hrWhat the 20 BTU/f…
Head size to buy6,000BTU/hr
Calculated load200 ft² × 23.9 BTU/ft²4,790BTU/hr
BTU per square foot hereinterpolated from Norfolk's 1,984 cooling degree days23.9BTU/ft²
What the 20 BTU/ft² rule givesthis room needs 20% more than the rule says4,000BTU/hr
Summer design temperature93°F
Winter design temperaturea mini split heats too — this is the number that decides whether it can carry the room alone21°F
Summer day–night swinga humid climate15°F
Days at or above 90°F34days/yr
Oversize from the size stepa big step — read the note25%

Notes

  • The "20 BTU per square foot" rule is a Midwest number. Norfolk runs 1,984 cooling degree days, which works out to 23.9 BTU/ft² — so for this bedroom the rule is 20% short. A single national figure has to be wrong somewhere, and this is where.
  • Bedroom: the room where oversizing hurts most — quiet, low load, long runtimes wanted.
  • 6,000 BTU/hr is 25% above the load, and the gap between head sizes is wide — this is already the smallest head. In a single room that matters more than it would on a central system: there are no other rooms to absorb the excess capacity. If the room is well insulated and shaded, the smaller head is usually the better buy, and modern inverter compressors modulate down far better than they modulate up.
  • Norfolk is humid — summer nights stay within 15°F of the day's high, the signature of humid air. A meaningful share of this head's work is removing moisture, and it only removes moisture while it is running. This is the climate where an oversized head produces a room that reads cold and feels clammy.
  • Do not forget the winter side. Norfolk designs to 21°F. A cold-climate rated head will hold most of its capacity there, but a standard one will not — ask for the capacity at 21°F in writing.
  • Where these numbers come from. Norfolk International Airport, 10 km from downtown Norfolk, daily records 2015–2024. Design temperatures are calibrated against published ASHRAE values at eight airports and land within about 2°F of them.

The short answer

A 200 square foot bedroom in Norfolk, VA needs a head of about 6,000 BTU per hour. The calculated load is 4,790 BTU/hr.

Where that number comes from

Norfolk, VA runs 1,984 cooling degree days a year, which puts the room at 23.9 BTU per square foot rather than the 20 BTU/ft² the generic charts use. Applied to this room the rule gives 4,000 BTU/hr.

The winter half of the question

Norfolk, VA designs to 21°F. A mini split is a heat pump, and its heating capacity falls as the outdoor temperature drops — the nameplate is measured at 47°F, not at the temperature you actually need it.

Sizing a single room is not sizing a house

There is no other room to absorb a mistake. An oversized head short-cycles, never runs long enough to dehumidify, and leaves the room cold and damp.