What size mini split does a 200 sq ft bedroom in Las Vegas, NV need?
200 ft² bedroom in Las Vegas, NV
6,000BTU/hr
5,546 BTU/hr of load at 27.7 BTU/ft² — the figure for 4,007 cooling degree days
| Head size to buy | 6,000BTU/hr |
|---|---|
| Calculated load200 ft² × 27.7 BTU/ft² | 5,546BTU/hr |
| BTU per square foot hereinterpolated from Las Vegas's 4,007 cooling degree days | 27.7BTU/ft² |
| What the 20 BTU/ft² rule givesthis room needs 39% more than the rule says | 4,000BTU/hr |
| Summer design temperature | 110°F |
| Winter design temperaturea mini split heats too — this is the number that decides whether it can carry the room alone | 32°F |
| Summer day–night swinga fairly dry climate | 23°F |
| Days at or above 90°F | 136days/yr |
| Oversize from the size stepwithin the normal step | 8% |
Notes
- The "20 BTU per square foot" rule is a Midwest number. Las Vegas runs 4,007 cooling degree days, which works out to 27.7 BTU/ft² — so for this bedroom the rule is 39% short. A single national figure has to be wrong somewhere, and this is where.
- Bedroom: the room where oversizing hurts most — quiet, low load, long runtimes wanted.
- 6,000 BTU/hr sits close to the load, which is where a mini split works best. Inverter equipment is happiest running long and slow at part load; it is the short, hard cycles of an oversized head that leave a room cold and damp.
- Las Vegas is dry — nights fall 23°F below the afternoon high, which only happens when there is little water in the air. Latent load is small, so nearly all of the head's capacity goes into temperature. A slightly undersized head is forgiving here: it simply runs longer.
- Do not forget the winter side. Las Vegas designs to 32°F. That is mild enough that heating capacity is not the constraint here; size for cooling and the heating follows.
- Where these numbers come from. McCarran International Airport, 13 km from downtown Las Vegas, daily records 2015–2024. Design temperatures are calibrated against published ASHRAE values at eight airports and land within about 2°F of them.
The short answer
A 200 square foot bedroom in Las Vegas, NV needs a head of about 6,000 BTU per hour. The calculated load is 5,546 BTU/hr.
Where that number comes from
Las Vegas, NV runs 4,007 cooling degree days a year, which puts the room at 27.7 BTU per square foot rather than the 20 BTU/ft² the generic charts use. Applied to this room the rule gives 4,000 BTU/hr.
The winter half of the question
Las Vegas, NV designs to 32°F. A mini split is a heat pump, and its heating capacity falls as the outdoor temperature drops — the nameplate is measured at 47°F, not at the temperature you actually need it.
Sizing a single room is not sizing a house
There is no other room to absorb a mistake. An oversized head short-cycles, never runs long enough to dehumidify, and leaves the room cold and damp.
Nearby sizes
- What size mini split does a 200 sq ft bedroom in Detroit, MI need?
- What size mini split does a 200 sq ft bedroom in New South Memphis, TN need?
- What size mini split does a 200 sq ft bedroom in Portland, OR need?
- What size mini split does a 200 sq ft bedroom in Memphis, TN need?
- What size mini split does a 300 sq ft bedroom in Las Vegas, NV need?
- What size mini split does a 200 sq ft living room in Las Vegas, NV need?
Read more
- Mini Split Blowing Cold Air in Heat Mode — Defrost, UsuallyEvery air-source heat pump does this. Knowing what a defrost cycle looks like is the difference between waiting ten minutes and calling somebody out.
- Mini Split Leaking Water Indoors — Four Causes, One CommonA cooling head makes a couple of litres a day. It leaves through a small pipe with no pump behind it, and that pipe is where nearly every leak starts.
- Multi-Zone Mini Split Not Cooling Every Room — The Minimum Output ProblemThe system is not underpowered. It is oversized for the one room that is calling, and multi-zone units handle that far worse than single-zone ones.