What size mini split does a 200 sq ft bedroom in Aliamanu / Salt Lakes / Foster Village, HI need?
| Head size to buy | 6,000BTU/hr |
|---|---|
| Calculated load200 ft² × 28.9 BTU/ft² | 5,772BTU/hr |
| BTU per square foot hereinterpolated from Aliamanu / Salt Lakes / Foster Village's 4,942 cooling degree days | 28.9BTU/ft² |
| What the 20 BTU/ft² rule givesthis room needs 44% more than the rule says | 4,000BTU/hr |
| Summer design temperature | 90°F |
| Winter design temperaturea mini split heats too — this is the number that decides whether it can carry the room alone | 62°F |
| Summer day–night swinga humid climate | 13°F |
| Days at or above 90°F | 13days/yr |
| Oversize from the size stepwithin the normal step | 4% |
Notes
- The "20 BTU per square foot" rule is a Midwest number. Aliamanu / Salt Lakes / Foster Village runs 4,942 cooling degree days, which works out to 28.9 BTU/ft² — so for this bedroom the rule is 44% short. A single national figure has to be wrong somewhere, and this is where.
- Bedroom: the room where oversizing hurts most — quiet, low load, long runtimes wanted.
- 6,000 BTU/hr sits close to the load, which is where a mini split works best. Inverter equipment is happiest running long and slow at part load; it is the short, hard cycles of an oversized head that leave a room cold and damp.
- Aliamanu / Salt Lakes / Foster Village is humid — summer nights stay within 13°F of the day's high, the signature of humid air. A meaningful share of this head's work is removing moisture, and it only removes moisture while it is running. This is the climate where an oversized head produces a room that reads cold and feels clammy.
- Do not forget the winter side. Aliamanu / Salt Lakes / Foster Village designs to 62°F. That is mild enough that heating capacity is not the constraint here; size for cooling and the heating follows.
- Where these numbers come from. Honolulu International Airport, 4 km from downtown Aliamanu / Salt Lakes / Foster Village, daily records 2015–2024. Design temperatures are calibrated against published ASHRAE values at eight airports and land within about 2°F of them.
The short answer
A 200 square foot bedroom in Aliamanu / Salt Lakes / Foster Village, HI needs a head of about 6,000 BTU per hour. The calculated load is 5,772 BTU/hr.
Where that number comes from
Aliamanu / Salt Lakes / Foster Village, HI runs 4,942 cooling degree days a year, which puts the room at 28.9 BTU per square foot rather than the 20 BTU/ft² the generic charts use. Applied to this room the rule gives 4,000 BTU/hr.
The winter half of the question
Aliamanu / Salt Lakes / Foster Village, HI designs to 62°F. A mini split is a heat pump, and its heating capacity falls as the outdoor temperature drops — the nameplate is measured at 47°F, not at the temperature you actually need it.
Sizing a single room is not sizing a house
There is no other room to absorb a mistake. An oversized head short-cycles, never runs long enough to dehumidify, and leaves the room cold and damp.
Nearby sizes
- What size mini split does a 200 sq ft bedroom in Dover, DE need?
- What size mini split does a 200 sq ft bedroom in Kailua, HI need?
- What size mini split does a 200 sq ft bedroom in Clovis, NM need?
- What size mini split does a 200 sq ft bedroom in Whitney, NV need?
- What size mini split does a 300 sq ft bedroom in Aliamanu / Salt Lakes / Foster Village, HI need?
- What size mini split does a 200 sq ft living room in Aliamanu / Salt Lakes / Foster Village, HI need?
Read more
- Mini Split Blowing Cold Air in Heat Mode — Defrost, UsuallyEvery air-source heat pump does this. Knowing what a defrost cycle looks like is the difference between waiting ten minutes and calling somebody out.
- Mini Split Leaking Water Indoors — Four Causes, One CommonA cooling head makes a couple of litres a day. It leaves through a small pipe with no pump behind it, and that pipe is where nearly every leak starts.
- Multi-Zone Mini Split Not Cooling Every Room — The Minimum Output ProblemThe system is not underpowered. It is oversized for the one room that is calling, and multi-zone units handle that far worse than single-zone ones.